购物车图片 购物车 CART
PRODUCTS
  • Insulation & Protection for Electrical T & D
  • Kitting Materials of Power Cable Joint & Termination
  • Switchgear Extension & Insulation
  • MV Plug-in Separable Connector Outside Cone & Inside Cone
  • MV/LV Power Cable Termination & Joint
  • HV Power Cable Termination & Joint
  • Heat Shrinkable Tube & Molded Shape
284
285
286
287
288
289
290
291
分类:
  • Product groups
    All
    Outage prevention line cover Bus bar insulation connection cover (Boot) Bus bar insulation tubing Bus bar insulation tape Bushing boot Bushing / Bus connection insulating covers
排序
默认
价格
销量
新品
活动:
全部
本月推荐
限时促销
热销商品
最新新品
价格:
仅显示有货
30 个商品
1 / 2
上一页 下一页
Products
  • 燃料:

    提升高度:

    Applications● Applied on overhead bare conductor line which pass   through the tunnel,bridge,tropic rain forest for improving   the insulating performance,preventing short-circuit.● Protect the bare conductor of the single-phase   27.5kV railway electrical system.     ● Provide protection for partial down-lead of the on-   column switch and the transformer.● Provide insulation protection for the transmission   and distribution line where necessary.

    年份:

    0

    工时:

    UELC—Overhead line coverUELC is a cold-applied wrap-around cover that provides retrofit insulation for overhead conductors to helpprevent electrical outages caused by incidental contact from tree branches or wildlife. UELC may be appliedselectively on problem spans to avoid costly conductor replacement. It is easy and quick for installation bythe hand tool, especially for the short length conductor in substations.Feature● Standard color: Red, black, other calor is availale for request.● Creepage extender to improve the electrical creepage distance.● Can be coated with sealant mastic inside to improve sealing performance.● Weatherability, insulating, anti-tracking, abrasion resistant and UV resistance.● Wide usage: four sizes cover the conductor size up to 1000mm².● Suitable environment temprature -10~100℃ after Irradiation crosslinked process.● Wrap around with sefl-fusing insulation tape UEJ80 at the end of overhead line cover can avoid slipping   after installation.

    荷载:

    Cold-applied wrap-around cover that provides retrofit insulation for overhead conductors.
    价格仅会员可见 ¥0
  • 燃料:

    提升高度:

    ApplicationProvide protection for substantionProvide protection for bridgeProvide protection for railway

    年份:

    0

    工时:

    SSLC—Silicone split line coverUE-SSLC is designed mainly for Medium voltage networks, provides high quality electrical insulation forsubstation leads and jumpers electrical insulation.Flexibility allows installation tight bends which makes it ideal for substation application. Designed split foreasy installation.Can also be used as insulation supplementary for high voltage networks.Installation over bare conductorAs suppliedAfter fitting

    荷载:

    Silicone split line cover.
    价格仅会员可见 ¥0
  • 燃料:

    提升高度:

    年份:

    0

    工时:

    [ Inquiry Notes: Please provide dimension A/B/C/D/E  (mm) in the drawing ]BBIC—Bus Bar Insulation Connection Cover up to 40.5kVBus bar insulation connection cover “UE-BBIC”, A wide range of preformed covers are available for most ofsubstation equipment connections. Customised covers can be made simply and economically by forming ourinsulation materials.Installation is easy with no need to disconnect bus bars. Such covers are held in place with UV- stabilizedplastic nuts and bolts, latches or cable ties, and be easily removed for maintenance. Suitable for applicationsup to 40.5kV.Substation equipment is vulnerable to flashovers caused by accidental bridging of phases, or phase to earth.Usually made by birds, animals, vegetation or airborne debris, flashovers can be very expensive in termsof damage to equipment, reduced reliability. Most of event of this nature can be prevented by covering thestrategically vulnerable bare metalwork.Insulation for energized bus components and connections shall consist of tubing, tape, and other devices thatare factory-engineered to meet applicable switchgear performcance requirements. UE bus bar connectioncovers "BBIC" provide high dielectric strength, adequate thermal endurance at bus operating temperatures,and tracking and erosion resistance.

    荷载:

    Bus bar insulation connection cover up to 40.5kV.
    价格仅会员可见 ¥0
  • 燃料:

    提升高度:

    年份:

    0

    工时:

    [ Inquiry Notes: Please provide dimension A/B/C/D/E  (mm) in the drawing ]BBIC—Bus Bar Insulation Connection Cover up to 40.5kVBus bar insulation connection cover “UE-BBIC”, A wide range of preformed covers are available for most ofsubstation equipment connections. Customised covers can be made simply and economically by forming ourinsulation materials.Installation is easy with no need to disconnect bus bars. Such covers are held in place with UV- stabilizedplastic nuts and bolts, latches or cable ties, and be easily removed for maintenance. Suitable for applicationsup to 40.5kV.Substation equipment is vulnerable to flashovers caused by accidental bridging of phases, or phase to earth.Usually made by birds, animals, vegetation or airborne debris, flashovers can be very expensive in termsof damage to equipment, reduced reliability. Most of event of this nature can be prevented by covering thestrategically vulnerable bare metalwork.Insulation for energized bus components and connections shall consist of tubing, tape, and other devices thatare factory-engineered to meet applicable switchgear performcance requirements. UE bus bar connectioncovers "BBIC" provide high dielectric strength, adequate thermal endurance at bus operating temperatures,and tracking and erosion resistance.

    荷载:

    Bus bar insulation connection cover for elbow right bus bar up to 40.5kV.
    价格仅会员可见 ¥0
  • 燃料:

    提升高度:

    年份:

    0

    工时:

    [ Inquiry Notes: Please provide dimension A/B/C/D/E  (mm) in the drawing ]BBIC—Bus Bar Insulation Connection Cover up to 40.5kVBus bar insulation connection cover “UE-BBIC”, A wide range of preformed covers are available for most ofsubstation equipment connections. Customised covers can be made simply and economically by forming ourinsulation materials.Installation is easy with no need to disconnect bus bars. Such covers are held in place with UV- stabilizedplastic nuts and bolts, latches or cable ties, and be easily removed for maintenance. Suitable for applicationsup to 40.5kV.Substation equipment is vulnerable to flashovers caused by accidental bridging of phases, or phase to earth.Usually made by birds, animals, vegetation or airborne debris, flashovers can be very expensive in termsof damage to equipment, reduced reliability. Most of event of this nature can be prevented by covering thestrategically vulnerable bare metalwork.Insulation for energized bus components and connections shall consist of tubing, tape, and other devices thatare factory-engineered to meet applicable switchgear performcance requirements. UE bus bar connectioncovers "BBIC" provide high dielectric strength, adequate thermal endurance at bus operating temperatures,and tracking and erosion resistance.

    荷载:

    Bus bar insulation connection cover for splice inline bus bar up to 40.5kV.
    价格仅会员可见 ¥0
  • 燃料:

    提升高度:

    年份:

    0

    工时:

    [ Inquiry Notes: Please provide dimension A/B/C/D/E  (mm) in the drawing ]BBIC—Bus Bar Insulation Connection Cover up to 40.5kVBus bar insulation connection cover “UE-BBIC”, A wide range of preformed covers are available for most ofsubstation equipment connections. Customised covers can be made simply and economically by forming ourinsulation materials.Installation is easy with no need to disconnect bus bars. Such covers are held in place with UV- stabilizedplastic nuts and bolts, latches or cable ties, and be easily removed for maintenance. Suitable for applicationsup to 40.5kV.Substation equipment is vulnerable to flashovers caused by accidental bridging of phases, or phase to earth.Usually made by birds, animals, vegetation or airborne debris, flashovers can be very expensive in termsof damage to equipment, reduced reliability. Most of event of this nature can be prevented by covering thestrategically vulnerable bare metalwork.Insulation for energized bus components and connections shall consist of tubing, tape, and other devices thatare factory-engineered to meet applicable switchgear performcance requirements. UE bus bar connectioncovers "BBIC" provide high dielectric strength, adequate thermal endurance at bus operating temperatures,and tracking and erosion resistance.

    荷载:

    Bus bar insulation connection cover for insulator througth multi bar up to 40.5kV.
    价格仅会员可见 ¥0
  • 燃料:

    提升高度:

    年份:

    0

    工时:

    [ Inquiry Notes: Please provide dimension A/B/C/D/E  (mm) in the drawing ]BBIC—Bus Bar Insulation Connection Cover up to 40.5kVBus bar insulation connection cover “UE-BBIC”, A wide range of preformed covers are available for most ofsubstation equipment connections. Customised covers can be made simply and economically by forming ourinsulation materials.Installation is easy with no need to disconnect bus bars. Such covers are held in place with UV- stabilizedplastic nuts and bolts, latches or cable ties, and be easily removed for maintenance. Suitable for applicationsup to 40.5kV.Substation equipment is vulnerable to flashovers caused by accidental bridging of phases, or phase to earth.Usually made by birds, animals, vegetation or airborne debris, flashovers can be very expensive in termsof damage to equipment, reduced reliability. Most of event of this nature can be prevented by covering thestrategically vulnerable bare metalwork.Insulation for energized bus components and connections shall consist of tubing, tape, and other devices thatare factory-engineered to meet applicable switchgear performcance requirements. UE bus bar connectioncovers "BBIC" provide high dielectric strength, adequate thermal endurance at bus operating temperatures,and tracking and erosion resistance.

    荷载:

    Bus bar insulation connection cover up to 40.5kV.
    价格仅会员可见 ¥0
  • 燃料:

    提升高度:

    年份:

    0

    工时:

    [ Inquiry Notes: Please provide dimension A/B/C/D/E  (mm) in the drawing ]BBIC—Bus Bar Insulation Connection Cover up to 40.5kVBus bar insulation connection cover “UE-BBIC”, A wide range of preformed covers are available for most ofsubstation equipment connections. Customised covers can be made simply and economically by forming ourinsulation materials.Installation is easy with no need to disconnect bus bars. Such covers are held in place with UV- stabilizedplastic nuts and bolts, latches or cable ties, and be easily removed for maintenance. Suitable for applicationsup to 40.5kV.Substation equipment is vulnerable to flashovers caused by accidental bridging of phases, or phase to earth.Usually made by birds, animals, vegetation or airborne debris, flashovers can be very expensive in termsof damage to equipment, reduced reliability. Most of event of this nature can be prevented by covering thestrategically vulnerable bare metalwork.Insulation for energized bus components and connections shall consist of tubing, tape, and other devices thatare factory-engineered to meet applicable switchgear performcance requirements. UE bus bar connectioncovers "BBIC" provide high dielectric strength, adequate thermal endurance at bus operating temperatures,and tracking and erosion resistance.

    荷载:

    Bus bar insulation connection cover up to 40.5kV.
    价格仅会员可见 ¥0
  • 燃料:

    提升高度:

    年份:

    0

    工时:

    [ Inquiry Notes: Please provide dimension A/B/C/D/E  (mm) in the drawing ]BBIC—Bus Bar Insulation Connection Cover up to 40.5kVBus bar insulation connection cover “UE-BBIC”, A wide range of preformed covers are available for most ofsubstation equipment connections. Customised covers can be made simply and economically by forming ourinsulation materials.Installation is easy with no need to disconnect bus bars. Such covers are held in place with UV- stabilizedplastic nuts and bolts, latches or cable ties, and be easily removed for maintenance. Suitable for applicationsup to 40.5kV.Substation equipment is vulnerable to flashovers caused by accidental bridging of phases, or phase to earth.Usually made by birds, animals, vegetation or airborne debris, flashovers can be very expensive in termsof damage to equipment, reduced reliability. Most of event of this nature can be prevented by covering thestrategically vulnerable bare metalwork.Insulation for energized bus components and connections shall consist of tubing, tape, and other devices thatare factory-engineered to meet applicable switchgear performcance requirements. UE bus bar connectioncovers "BBIC" provide high dielectric strength, adequate thermal endurance at bus operating temperatures,and tracking and erosion resistance.

    荷载:

    Bus bar insulation connection cover up to 40.5kV.
    价格仅会员可见 ¥0
  • 燃料:

    提升高度:

    年份:

    0

    工时:

    [ Inquiry Notes: Please provide dimension A/B/C/D/E  (mm) in the drawing ]BBIC—Bus Bar Insulation Connection Cover up to 40.5kVBus bar insulation connection cover “UE-BBIC”, A wide range of preformed covers are available for most ofsubstation equipment connections. Customised covers can be made simply and economically by forming ourinsulation materials.Installation is easy with no need to disconnect bus bars. Such covers are held in place with UV- stabilizedplastic nuts and bolts, latches or cable ties, and be easily removed for maintenance. Suitable for applicationsup to 40.5kV.Substation equipment is vulnerable to flashovers caused by accidental bridging of phases, or phase to earth.Usually made by birds, animals, vegetation or airborne debris, flashovers can be very expensive in termsof damage to equipment, reduced reliability. Most of event of this nature can be prevented by covering thestrategically vulnerable bare metalwork.Insulation for energized bus components and connections shall consist of tubing, tape, and other devices thatare factory-engineered to meet applicable switchgear performcance requirements. UE bus bar connectioncovers "BBIC" provide high dielectric strength, adequate thermal endurance at bus operating temperatures,and tracking and erosion resistance.

    荷载:

    Bus bar insulation connection cover up to 40.5kV.
    价格仅会员可见 ¥0
  • 燃料:

    提升高度:

    年份:

    0

    工时:

    [ Inquiry Notes: Please provide dimension A/B/C/D/E  (mm) in the drawing ]BBIC—Bus Bar Insulation Connection Cover up to 40.5kVBus bar insulation connection cover “UE-BBIC”, A wide range of preformed covers are available for most ofsubstation equipment connections. Customised covers can be made simply and economically by forming ourinsulation materials.Installation is easy with no need to disconnect bus bars. Such covers are held in place with UV- stabilizedplastic nuts and bolts, latches or cable ties, and be easily removed for maintenance. Suitable for applicationsup to 40.5kV.Substation equipment is vulnerable to flashovers caused by accidental bridging of phases, or phase to earth.Usually made by birds, animals, vegetation or airborne debris, flashovers can be very expensive in termsof damage to equipment, reduced reliability. Most of event of this nature can be prevented by covering thestrategically vulnerable bare metalwork.Insulation for energized bus components and connections shall consist of tubing, tape, and other devices thatare factory-engineered to meet applicable switchgear performcance requirements. UE bus bar connectioncovers "BBIC" provide high dielectric strength, adequate thermal endurance at bus operating temperatures,and tracking and erosion resistance.

    荷载:

    Bus bar insulation connection cover up to 40.5kV.
    价格仅会员可见 ¥0
  • 燃料:

    提升高度:

    年份:

    0

    工时:

    [ Inquiry Notes: Please provide dimension A/B/C/D/E  (mm) in the drawing ]BBIC—Bus Bar Insulation Connection Cover up to 40.5kVBus bar insulation connection cover “UE-BBIC”, A wide range of preformed covers are available for most ofsubstation equipment connections. Customised covers can be made simply and economically by forming ourinsulation materials.Installation is easy with no need to disconnect bus bars. Such covers are held in place with UV- stabilizedplastic nuts and bolts, latches or cable ties, and be easily removed for maintenance. Suitable for applicationsup to 40.5kV.Substation equipment is vulnerable to flashovers caused by accidental bridging of phases, or phase to earth.Usually made by birds, animals, vegetation or airborne debris, flashovers can be very expensive in termsof damage to equipment, reduced reliability. Most of event of this nature can be prevented by covering thestrategically vulnerable bare metalwork.Insulation for energized bus components and connections shall consist of tubing, tape, and other devices thatare factory-engineered to meet applicable switchgear performcance requirements. UE bus bar connectioncovers "BBIC" provide high dielectric strength, adequate thermal endurance at bus operating temperatures,and tracking and erosion resistance.

    荷载:

    Bus bar insulation connection cover up to 40.5kV.
    价格仅会员可见 ¥0
  • 燃料:

    提升高度:

    Application

    年份:

    0

    工时:

    BBIT-M / BBIT-R—Medium wall busbar insulation tube up to 36kVMade from specially formulated radiation cross-linked halogen free compounds. It can provide highresistance to tracking and arcing, as well as to enhance the insulation properties of bus bar in switchgear andsubstation. Suitable for application in insulating medium voltage bus bars up to 36kV.Feature● Minimum shrink temperature: 120°C.● Halogen free, UV resistant.● Excellent flexibility, can be used on irregular shapes without creasing of tubing occurring.● Easily slid into place, even around several bends and on awkward shapes.

    荷载:

    Medium wall busbar insulation tube up to 36kV.
    价格仅会员可见 ¥0
  • 燃料:

    提升高度:

    Application

    年份:

    0

    工时:

    BBIT-M / BBIT-R—Medium wall busbar insulation tube up to 36kVMade from specially formulated radiation cross-linked halogen free compounds. It can provide highresistance to tracking and arcing, as well as to enhance the insulation properties of bus bar in switchgear andsubstation. Suitable for application in insulating medium voltage bus bars up to 36kV.Feature● Minimum shrink temperature: 120°C.● Halogen free, UV resistant.● Excellent flexibility, can be used on irregular shapes without creasing of tubing occurring.● Easily slid into place, even around several bends and on awkward shapes.

    荷载:

    Medium wall busbar insulation tube up to 36kV.
    价格仅会员可见 ¥0
  • 燃料:

    提升高度:

    Application

    年份:

    0

    工时:

    BBIT-H—Heavy wall busbar insulation tube up to 36kV.● Minimum shrink temperature: 120°C.● Halogen free, UV resistant.● Excellent flexibility, can be used on irregular shapes without creasing of tubing occurring.● Easily slid into place, even around several bends and on awkward shapes.

    荷载:

    Heavy wall busbar insulation tube up to 36kV.
    价格仅会员可见 ¥0
  • 燃料:

    提升高度:

    Technical data

    年份:

    0

    工时:

    UE-BBIT-L—Low voltage busbar insulation tubeSpecially designed formulation ensure the tubing to meet the standard of UL 224 and CSA C 22.2. Free fromenvironment harmful substance as PBB’s, PBBO’s, PBBE’s and toxic heavy metal in its components, makesit meet the requirement of environment protection. In case of burning no Dioxin is produced. The propertiesof low shrinking temperature, flexibility and superior mechanical strength make them widely used in the fieldof bus bar insulation, electronics, communication, automobile etc.Feature● Shrink ratio 2:1 and 3:1● Approval:  125°C VW-1 600V File No. E204071● Meet: RoHs, Sony-SS-00259● Minimum shirnk temperature:70°C, Minimum fully recovery temperature:100°C● Standard color: Black, Red, Blue, Yellow, Green, White and other colors are available on request

    荷载:

    Low voltage busbar insulation tube.
    价格仅会员可见 ¥0
CONTACT Contact us
Contact us immediately
  • 您的姓名:
  • *
  • E-mail:
  • *
  • 公司名称:
  • *
  • 地址:
  • *
  • 电话:
  • *
  • QQ:
  • 传真:
  • *
  • 邮政编码:
  • *
  • 留言主题:
  • *
  • 详细说明:
  • *
联系方式
  • 电话:4006-971-972
  • 传真:4000-000-366
  • 网址:www.niumowang.com
  • 地址:深圳市宝安区航城大道西乡光电研发大厦二层
CONTACT
United Electric Co., Ltd. 515 Saiba Bldg. No.16, Keji North 2nd Road, Nanshan District, Shenzhen 518057, Guangdong, China.
Tel: +86 755 26419370 / 26419390           Fax: +86 755 26414580
export@ueaccessory.com
SHARING
Copyright ©2019 - 2022 United Electric Co
犀牛云提供企业云服务
X
1

QQ设置

3

SKYPE 设置

4

阿里旺旺设置

1

QQ设置

5

电话号码管理

  • 4006-971-972
6

二维码管理

  • Leave Message
999999

邮箱

CONTACT US
  • Name:
  • *
  • Phone:
  • *
  • Email:
  • *
  • Message:
  • *
We won't share your into with third parties
展开